• Product Name :

    TS-CSTV24 Satellite TV Surge Protector

  • Instruction

    ♦ TS-CTV24 Satellite TV Surge Protector is designed according to IEC 61643-21; GB 18802.21; YD/T 1542 and apply in 75Ω satellite and cable TV system.

    ♦ Product Size

    TS-CSTV24-Satellite-TV-Surge-Protector-Best-Price


    ♦ Basic Circuit Diagram

    TS-CSTV24-Satellite-TV-Surge-Protector-In-China


    ♦ Technical Data 

    Model 

     

    TS-CSTV24 

    Rated voltage (max. continuous voltage) 

    Uc

    24V- 

    Nominal current

    IL

    2A

    Lightning Impulse Current (10/350) 

    Iimp

    0.5KA 

    Nominal discharge current (8/20) 

    In

    2.5KA 

    Voltage protection level at In 

    Up

    ≤300V (line-shield)   

    Voltage protection level at 1kV/ms 

    Up

    ≤60V (line-shield)   

    Frequency range

    F

    5-3000MHz

    Insertion loss

    aE

    1.2dB (5-862MHz)

    1.4dB (862-2400MHz)       2dB (2400-3000MHz)

    Return loss (input/output)

    aR

    ≥ 14dB (5-47MHz)

    ≥ 18dB (47-3000MHz)

    Shield attenuation

    aS

    ≥ 85dB (5-300MHz)        ≥ 80dB (300-470MHz)

    ≥ 75dB (470-1000MHz)     ≥ 55dB (1000-3000MHz)

    Surge impedance

    Z

    75Ω

    Response time

    R

    ≤ 1ns (line-shield)

    Operating temperature range 

     

    -40°C...+80°C 

    Connection (input / output) 

     

    F socket 

    Shield earthing

     

    Screw terminal

    Mounting on 

     

    35mm DIN rail 

    Enclosure material 

     

    Aluminum 

    Standards 

     

    IEC 61643-21;  GB 18802.21;  YD/T 1542 

    Certification

     

    CE(LVD,EMC)

     

     MAIN CHARACTER 

    1, Good discharge capacity, low voltage protection level

    2, Multiple protection, quick response, no interruption

    3, F socket connection, easy for installation

    INSTALLATION INSTRUCTION

    1. This TV Surge Protector is connected in series to the protected device.

    2. Mount the TV Surge Protector on 35 mm DIN rail.

    3. The out terminal should be connected to the protected devices.

    4. TV Surge Protector's earthing terminal must be connected to nearby earthing BusBar or the metal earthing enclosure of protected device.

    5. After above, you should ensure the circuit is functioning.

    Regularly inspect the operating status, especially after lightning. Once the communication is off,  electrician should check/replace the TV Surge Protector.

     

    INSTALLATION DIAGRAM

    TS-CSTV24-Satellite-TV-Surge-Protector-Cheap

    WARNING:

    1, The device must be installed by electrically skilled person, conforming to national standards and safety regulations.

    2, It is recommended that installation should be done under power off condition.