• Product Name :

    TS-DP10 LSA110 Telephone Surge Protection Device

  • Instruction

    ♦ TS Series LSA-PLUS Telephone Surge Protection Device is designed according to GB 18802.21 / IEC 61643-21,based on the LSA-PLUS wiring technology,easy for installation. it can provide surge voltage protection for 10-pair of conductors or 20 single conductors. Mainly used for telephone system or measurement and control system.

    ♦ CUSTOM-MADE CIRCUIT、Voltage & Technical Data AVAILABLE

    ♦ Product Size

    TS-DP10-LSA110-Telephone-Surge-Protection-Device-Customized


    ♦ Basic Circuit Diagram

    TS-DP10-LSA110-Telephone-Surge-Protection-Device-In-China

    ♦ Technical Data 

    Model

     

    TS-DP10 LSA110 

    Nominal voltage

    Un

    110V-

    Rated voltage (max. continuous voltage)

    Uc

    120V- / 84.6V~

    Nominal current

    IL

    180mA

    Nominal discharge current (8/20)

    In

    5kA (per line)

    Voltage protection level at 1KV/µS

    Up

    ≤ 180V (l ine-PG)

    Response time

    tA

    ≤ 1ns (line-line)

    ≤ 1ns (line-PG)

    Bandwidth

    fG

    10.0MHz ( line -PG)

    Series impedance per line

    R

    22Ω

    Capacitance

    C

    ≤1nF (l ine-PG)

    Relative humidity

     

    ≤95% (25°C)

    Operating temperature range

     

    -40°C~ - +80°C

    Pluggable into

     

    LSA-PLUS disconnection block

    Earthing via

     

    Earthing BusBar

    Enclosure material

     

    Orange thermoplastic material  , UL94-V0

    Standards

     

    IEC 61643-21 & GB 18802.21

    Certification

     

    CE (LVD, EMC & RoHS)

     

     MAIN CHARACTER 

    1, Good transmission

    2, Decoupling resistance integrated

    3, For installing at LPZ 0B-2 or higher 

    Installation instruction 

    1.The Telephone Surge Protection Device must be installed in correct direction.

    2.Plug earthing BusBar into input terminal of LSA-PLUS disconnection block

    3.Plug this product into the jack of LSA-PLUS disconnection block;make sure earthing terminal is

       contacted fully with earthing BusBar.

    Regularly inspect the operating status, especially after lightning. Once the communication is off, electrician should check/replacethe SPD. 

    Installation diagram

    TS-DP10-LSA110-Telephone-Surge-Protection-Device-Picture

    WARNING 

    1. The device must be installed by electrically skilled person, conforming to national standards and 

       safety regulations. 

    2. It is recommended that installation should be done under power off condition.