• Product Name :

    TS-RSP Series RS485-RS232 Surge Suppressor

  • Instruction

     TS-RSP series RS485/RS232 Surge Suppressor for D-SUB Information Technology System Protection 

    INTRODUCTION: TS-RSP series RS485/RS232 surge suppressor is designed according to IEC 61643-21; GB 18802.21; YD/T 1542. used at LPZ 2-3 boundary, provide surge protection for RS485, RS422 or RS232 signal devices from damages, such as surge voltages, operating over voltages, electrostatic discharging and so on. 

    ♦ Product-Size-Basic Circuit Diagram

    TS-RSP-Series-RS485-RS232-Surge-Suppressor-For-sale

    ♦ Technical Data 

    Model 

     

    TS-RSP9 

    TS-RSP15 

    TS-RSP25 

    TS-RSP37 

    Nominal voltage 

    Un

    12V- 

    5V-

    12V-

    48V-

    Rated voltage (max. continuous voltage) 

    Uc

    15V- 

    8V-

    15V-

    55V-

    Lightning impulse current (10/350)

    In

    /

    /

    /

    2.5KA (line-SG)

    Nominal discharge current  (8/20) 

    In

    100A (line-SG) 

    200A (line-SG)

    100A (line-SG)

    3KA (line-SG)

    Nominal discharge current (8/20) 

    In

    100A (SG-PG) 

    800A (SG-PG)

    100A (SG-PG)

     

    Max. discharge current (8/20)

    Imax

    200A (line-SG)

    400A (line-SG)

    200A (line-SG)

    5KA (line-SG)

    Max. discharge current (8/20)

    Imax

    200A (SG-PG)

    1.3KA (SG-PG)

    200A (SG-PG)

     

    Voltage protection level at In  

    Up

    ≤24V (line-SG)       

    ≤200V (SG-PG) 

    ≤16V (line-line)

    ≤16V (line-SG)       

    ≤16V (SG-PG)

    ≤24V(line-SG)       

    ≤200V(SG-PG)

    ≤120V (line-PG)

    Voltage protection level at 1kV/ms  

    Up

    ≤21V (l ine-SG)       

    ≤90V (SG-PG) 

    ≤11V (line-line)

    ≤11V (line-SG)       

    ≤11V (SG-PG)

    ≤21V(l ine-SG)       

    ≤90V (SG-PG)

    ≤100V (line-PG)

    Bandwidth

     

    10 MHz

    4 MHz

    10 MHz

    22 MHz (Series impedance per line (R)

    Response time 

    tA

    ≤1ns (line-SG)        

    ≤1ns (SG-PG) 

    ≤1ns (line-SG)        

    ≤1ns (SG-PG)

    ≤1ns (line-SG)        

    ≤1ns (SG-PG)

    ≤1ns(line-SG)        ≤25ns (SG-PG)

    Max. data transmission rates 

    Vs

    1Mbits/s 

    Operating temperature range 

     

    -40°C...+80°C 

    Relative humidity

     

    ≤ 95% (25°C)

    Protective lines

     

    Line: 8/ SG/PG

    2 two-core lines

    7/SG/PG

    Line:7/8/25/26/27, PG:12/20/30

    Pinning

     

    Line: 1/2/3/4/6/7/8/9,    SG: 5 (standby lines disconnected)

    2/9 1st pair;      4/11 2nd pair; 8:SG: 1:PG (standby lines disconnected )

    Line: 2/3/4/6/7/8/20, SG: 7 (standby lines disconnected )

    Line: 7/8/25/26/27 (standby lines disconnected )

    Mounting in

     

    D-Sub, 2 threaded screws

    D-Sub, 2 threaded screws/35mm Din Rail

    Connection (input / output) 

     

    D-sub 9 socket/plug

    D-sub 15 socket/plug

    D-sub 25 socket/plug

    D-sub 37 socket/plug

    Shield earthing

     

    Outgoing cable 1.5mm²x 300mm

    Enclosure material

     

    Plastic, metallised

    Dimension

     

    64mm x 35.5mm x 21mm

    Standards

     

    IEC 61643-21; GB 18802.21; YD/T 1542

    Certification

     

    CE(EMC, LVD)

     MAIN CHARACTER 

    1, High discharge capacity, low voltage protection level, quick response

    2, Do not impact the normal work of data management devices and system

    3, Apply for high speed transmission devices

    NSTALLATION INSTRUCTION 

    1. This RS485/RS422/RS232 surge suppressor is connected in series to the protected device, installation in the partition of LPZ 2-3 interface;

    In order to prevent lightning induction, LPZ 0A -1 and LPZ 1-2 interface must install additional surge protection products.

    2. The out terminal should be connected to the protected devices.

    3. SPD's earthing lead must be connected to nearby earthing BusBar or the metal earthing enclosure of protected device.

    4. After above, you should ensure the circuit is functioning.

    Regularly inspect the operating status, especially after lightning. Once the communication is off, electrician should check/replace the SPD.

    TS-RSP9 INSTALLATION DIAGRAM

    TS-RSP-Series-RS485-RS232-Surge-Suppressor-Professional-Manufacturer

    TS-RSP15 INSTALLATION DIAGRAM

    TS-RSP-Series-RS485-RS232-Surge-Suppressor-Manufacturer

    TS-RSP25 INSTALLATION DIAGRAM

    TS-RSP-Series-RS485-RS232-Surge-Suppressor-For-sale

    TS-RSP37 INSTALLATION DIAGRAM

    TS-RSP-Series-RS485-RS232-Surge-Suppressor-Cheap

    WARNING:

    1. The device must be installed by electrically skilled person, conforming to national standards and safety regulations.

    2. It is recommended that installation should be done under power off condition.